Title of article :
A Hybrid Enzyme Biosensor Based on Sulfite Oxidase and Glucose Oxidase for the Analyzing of Sulfite and Glucose
Author/Authors :
Sezginturk، Mustafa Kemal نويسنده , , Alaçam، Sencer نويسنده Ege University, Faculty of Science, Biochemistry Department35100,Bornova- ?zmir/Turkey , , Altu?، Ca?r? نويسنده Ege University, Faculty of Science, Biochemistry Department35100,Bornova- ?zmir/Turkey , , Akbayirli، P?nar نويسنده Ege University, Faculty of Science, Biochemistry Department35100,Bornova- ?zmir/Turkey , , Dinckaya، Erhan نويسنده ,
Issue Information :
دوماهنامه با شماره پیاپی سال 2012
Pages :
10
From page :
153
To page :
162
Abstract :
In this study, we developed a hybrid biosensor based on sulfite oxidase and glucose oxidase for determination of sulfite and glucose. The principle of the measurements was based on the determination of the decrease in the differentiation of oxygen level which had been caused by the catalytic reactions of the enzymes in the bioactive layer of the biosensor. The biosensor showed a linear response for an interval of sulfite concentration between 1×10-4 and 1.75×10-3 M and for glucose concentrations between 2.5×10-5 and 1.25×10-3 M. After some optimum and characterization studies, the proposed biosensor was applied to the determination of sulfite and glucose in certain real samples, blood and pickle water.
Journal title :
Analytical and Bioanalytical Electrochemistry
Serial Year :
2012
Journal title :
Analytical and Bioanalytical Electrochemistry
Record number :
691034
Link To Document :
بازگشت