Title of article :
Bronchial Rn dose survey for residences
Author/Authors :
K. N. Yu، نويسنده , , B. M. F. Lau، نويسنده , , Z. J. Guan، نويسنده , , T. Y. Lo، نويسنده , , E. C. M. Young، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2001
Abstract :
The bronchial dosimeter for Rn progeny proposed by Yu and Guan in 1998 was employed to survey the bronchial dose from Rn progeny in 30 residences in Hong Kong. An average bronchial deposition fraction of Rn progeny was obtained as 0.0334, which gave an average dose conversion factor (DCF) of 8.5 mSv WLM−1. The mean values of potential α energy concentration (PAEC) deposited in the tracheobronchial region (PAECT−B), total PAEC in air (PAECT), annual effective dose (E), concentration of Rn gas (RC) and annual dose conversion factor (ADCF) for all the residential sites combined were 0.11±0.05, 3.1±1.4 mWL, 1.2±0.5 mSv yr−1, 23±10 Bqm−3 and 0.055±0.020 (mSv yr−1 per Bqm−3), respectively, with air-conditioned sites (AC sites) and non-AC sites having significantly different mean ADCF values. The indoor relative humidity affected PAECT and RC PAECT−B and E with high confidence levels (>95%).
Keywords :
Dose conversion factor , RN , dose , Dosimeter , Lung model , deposition
Journal title :
Journal of Environmental Radioactivity
Journal title :
Journal of Environmental Radioactivity