Abstract :
The use of the xenon isotopes for detection of nuclear explosions is of great interest for monitoring compliance with the comprehensive nuclear-test-ban treaty (CTBT). Recently, the automated radioxenon sampler-analyzer (ARSA) was tested at the Institute for Atmospheric Radioactivity (IAR) in Freiburg, Germany to ascertain its use for the CTBT by comparing its results to laboratory-based analyses, determining its detection sensitivity and analyzing its results in light of historical xenon isotope levels and known reactor operations in the area. Xe-133 was detected nearly every day throughout the test at activity concentrations ranging between approximately 0.1 mBq/m3 to as high as 120 mBq/m3. Xe-133m and 135Xe were also detected occasionally during the test at concentrations of less than 1 to a few mBq/m3.
Keywords :
Xenon , Nuclear explosion monitoring , Noble gas , Xe-133 , ARSA , CTBT , Radioxenon