Title of article :
Radon levels in Cyprus
Author/Authors :
I. Sarrou، نويسنده , , I. Pashalidis، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2003
Pages :
9
From page :
269
To page :
277
Abstract :
Radon levels in atmospheric and aquatic systems in Cyprus have recently been measured using the radon monitor Alpha Guard. Indoor and outdoor radon levels were obtained in situ, whereas analysis of radon concentrations in water was performed using tap and ground water samples collected from several areas of the island. The average value for outdoor and indoor radon concentration is 11±10 and 7±6 Bq m−3, respectively, and for tap and ground water 0.4 Bq l−1 and 1.4 Bq l−1, respectively. From these data the annual dose equivalent of airborne radon to the Cypriot population is about 0.19 mSv y−1, which is quite low compared to the total dose equivalent of natural and man-made ionising radiation in Cyprus. Radon levels in aquatic systems are relatively low due to an exhaustive utilisation of ground water resources and also to the increased input of desalinated sea water in the water distribution network and eventually into the ground water reservoirs.
Keywords :
Indoor and outdoor radon , Aquatic radon , Cyprus , dose equivalent
Journal title :
Journal of Environmental Radioactivity
Serial Year :
2003
Journal title :
Journal of Environmental Radioactivity
Record number :
706254
Link To Document :
بازگشت