Title of article
Dioxin levels in the emissions from municipal waste incinerators in Taiwan
Author/Authors
Moo-Been Chang، نويسنده , , Chung Han Lee، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 1998
Pages
8
From page
2483
To page
2490
Abstract
In this study, characteristics of dioxins emission from existing modern MWIs were evaluated via simultaneous sampling of flue gas and various types of fly ashes. Preliminary results showed that PCDDs congeners distributions were quite similar in flue gas and various types of ashes of both MWIs. PCDFs/PCDDs ratio in cyclone ash was lower than that in combustor ash or fabric filter ash excluding economizer ash of MWI-A. Similarly, PCDFs/PCDDs ratio in ESP ash was lower than that in boiler ash. PCDFs concentration was about 1.5 to 4.3 times higher than PCDDs concentration in flue gas of both MWIs. The mass balance factors of MWI-A (0.9 1.02) were clearly lower than that of MWI-B (7.71 15.63), indicating that de novo synthesis occurred under the operating conditions of ESP. In other words, MWIs equipped with ESP were less efficient in controlling PCDD/Fs emissions than that equipped with fabric filters.
Journal title
Chemosphere
Serial Year
1998
Journal title
Chemosphere
Record number
723657
Link To Document