• Title of article

    Column studies on transport of deicing additive benzotriazole in a sandy aquifer and a zerovalent iron barrier Original Research Article

  • Author/Authors

    Yu Jia، نويسنده , , Gijs D. Breedveld، نويسنده , , Per Aagaard، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2007
  • Pages
    10
  • From page
    1409
  • To page
    1418
  • Abstract
    Benzotriazole (BTA), a chemical with wide industrial applications, is a typical additive in deicer/anti-icer used at airport. To achieve a better understanding of the transport behaviour and environmental fate of BTA, laboratory column studies have been performed on subsoil samples from Oslo Airport, Gardermoen. To explore possibilities for aquifer remediation, BTA behaviour was also studied in a column of granular zerovalent iron (Fe0). The subsoil column study demonstrates a very limited retardation of BTA. Consecutive loadings of BTA of the subsoil column showed no change of the break-through curve (BTC) and complete desorption was observed. The sorption behaviour of BTA to metallic iron (Fe0) was rather complex. Considerable retardation was observed in the Fe0 column and repeated BTA loading resulted in an earlier break-through. Between 20% and 50% of the input concentration was retained permanently in the iron (Fe0) column. The BTA sorption to metallic iron was found to be enhanced by chloride which lowered the break-through concentration (i.e the C/C0 plateau). The fraction of BTA remaining in the iron column was found to vary with the flow rate, indicating a time dependant multilayer sorption mechanism. The steady increase in the amount of adsorbed BTA to the iron column during loading corresponds to a rather strong bonding of 4–15 BTA layers to the iron surface. A very slow desorption of BTA was observed; even after flushing with 753 pore volumes of BTA free water, 7.5% of the BTA remained in the column. A geochemical model was developed based on PHREEQC-2 to simulate the sorption and transport of BTA in the tested materials. The BTA sorption was modelled with Freundlich sorption isotherms, as earlier determined in batch experiments. A slight adjustment of the Freundlich parameters was required to fit the observed column break-through. However, our model was not able to simulate the long-term retainment of BTA in the granular iron columns. The simulations confirm the high mobility of BTA in groundwater aquifers and suggest that zerovalent iron could be used to retain a BTA plume, although oxidation of the sorbent might reduce the long-term performance of such a remediation scheme and slow desorption has been observed.
  • Keywords
    Benzotriazole , ub oil , PHREEQC-2 , aquifer , Tran port modeling , Zerovalent iron
  • Journal title
    Chemosphere
  • Serial Year
    2007
  • Journal title
    Chemosphere
  • Record number

    725536