Title of article :
Microtox® testing of pentachlorophenol in soil extracts and quantification by capillary electrochromatography (CEC) – A rapid screening approach for contaminated land
Author/Authors :
N. P. Cassells، نويسنده , , C. S. Lane، نويسنده , , M. Depala، نويسنده , , M. Saeed، نويسنده , , D. H. Craston، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2000
Pages :
10
From page :
609
To page :
618
Abstract :
An approach to rapid soil testing which involved the use of simple solvent extraction methods was developed. The analytes of interest were priority pollutants of low water solubility which could not be readily removed from the soil using water. Direct toxicity testing of the soil samples by Microtox® showed a high background toxicity which prevented realistic toxicity data from being obtained for the contaminants present. A range of different extraction solutions was used in an attempt to extract the contaminants while eliminating the matrix effects of the soil. It was necessary that the solvents selected for extraction of the soil samples were not of significant toxicity, as this could potentially mask the toxic effects of any compounds extracted from the soil. The extraction efficiencies of solvent systems were evaluated using pentachlorophenol (PCP) as a model compound of known toxicity in the Microtox® assay. A rapid and cost-effective method was developed in order to determine the amount of PCP recovered from the soil by the extraction solvents employed. This method consisted of a solid phase extraction (SPE) step followed by quantification using capillary electrochromatography (CEC). Recoveries were greater when a higher proportion of organic solvent (methanol) was used in the extraction process, and lowest when water was used. An extraction based on water could provide information on the potential for leaching of contaminants from the soil into nearby water bodies in an environmental setting. An organic solvent extraction method could indicate how much toxicity soil-dependent organisms might be exposed to through ingestion. Extraction based on 50% (v/v) methanol in water was considered to be the most suitable overall extraction solution for soil screening, given that this permitted extraction of the water-insoluble compound PCP at a level which was clearly toxic in the Microtox® assay while also retaining the capability to extract water-soluble contaminants.
Keywords :
solid phase extraction , capillary electrochromatography , pentachlorophenol , soil , Microtoxâ
Journal title :
Chemosphere
Serial Year :
2000
Journal title :
Chemosphere
Record number :
734929
Link To Document :
بازگشت