Title of article
Fate of PCDD/PCDF during mechanical–biological sludge treatment
Author/Authors
Sylwia Oleszek-Kudlak، نويسنده , , Mariusz Grabda، نويسنده , , Marianna Czaplicka، نويسنده , , Czeslawa Rosik-Dulewska، نويسنده , , Etsuro Shibata، نويسنده , , Takashi Nakamura، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2005
Pages
9
From page
389
To page
397
Abstract
In this preliminary study the seventeen 2,3,7,8-substituted congeners of PCDD/PCDF were analyzed at the inlet and outlet water and for three sewage sludge samples taken from different treatment stages to check behaviours of PCDD/PCDF at a municipal wastewater treatment plant (MWTP) in Poland. At the inlet (untreated sewage) water dominated PCDD congeners, whereas in the outlet (treated water) dominated the PCDF congeners. The octaCDD, 1,2,3,4,6,7,8-heptaCDD/CDF and octaCDF congeners dominated in all of the sludge samples. The total toxicity load gradually increased in the series excess, digested and dewatered sludge and amounted to 12.2, 14.4 and 16.9 ng I-TEQ kg−1.
Keywords
Wastewater , Sewage sludge , behaviour , PCDD/PCDF , MWTP