Title of article :
Comparative performances of conventional cyclones and a double cyclone with and without an electric field
Author/Authors :
K. S. Lim، نويسنده , , H. S. Kim، نويسنده , , K. W. Lee، نويسنده ,
Issue Information :
ماهنامه با شماره پیاپی سال 2004
Pages :
14
From page :
103
To page :
116
Abstract :
Two conventional cyclones with different vortex finder diameters and a double cyclone were used to evaluate and compare their collection efficiencies and the effects of varying the vortex finder lengths and flow rates. In addition, a series of experiments were conducted to investigate the characteristics of the collection efficiencies of the cyclones when different voltages were applied to the vortex finder. The collection efficiency of the conventional cyclone with a smaller vortex finder diameter was higher, and that with a smaller vortex finder length was also higher when no voltage was applied. However, the collection efficiency properties were reversed when a voltage was applied and electric field was formed. The collection efficiency of the double cyclone increased greatly with increases in the applied voltage and decreases in the flow rate, and was the highest of all the cyclones when the same voltage and flow rates were applied. However, the collection efficiency of the double cyclone, with no applied voltage, was lower than that of the conventional cyclone with the 7-mm vortex finder diameter.
Keywords :
Electric field , Double cyclone , Collection effciency properties , Applied voltage
Journal title :
Journal of Aerosol Science
Serial Year :
2004
Journal title :
Journal of Aerosol Science
Record number :
742885
Link To Document :
بازگشت