• Title of article

    Development of a radon-aerosol chamber at NIRS—general design and aerosol performance

  • Author/Authors

    Hirokazu Ichitsubo، نويسنده , , Yuji Yamada، نويسنده , , Michikuni Shimo، نويسنده , , Akira Koizumi، نويسنده ,

  • Issue Information
    ماهنامه با شماره پیاپی سال 2004
  • Pages
    16
  • From page
    217
  • To page
    232
  • Abstract
    A radon-aerosol chamber having an inner volume of approximately 25 m3 has been developed at the National Institute of Radiological Sciences (NIRS). The chamber is designed to control temperature, relative humidity, aerosol concentration, radon concentration, and pressure differentials between inside and outside the chamber. We evaluated its performance as an aerosol chamber. Temperature and relative humidity can be controlled from 278 to 303 K, and 30% to 90%, respectively, and pressure differentials between inside and outside the chamber can be maintained at negative values. Temperature and relative humidity fluctuations are very small. The concentration of particles inside the chamber can be controlled from 108 to 1010 m−3. Particle concentrations and distributions are very stable. The particle concentration fluctuation is within the statistical error of the TSI CPC3010 particle counter. Changes in temperature and relative humidity had little effect on particle concentrations and their distributions.
  • Keywords
    Radon control , Environmental control , 222Rn , Radon-aerosol chamber , Aerosol particle concentration control