Title of article :
Passive measurement of coarse particulate matter, PM10–2.5
Author/Authors :
Darrin K. Ott، نويسنده , , William Cyrs، نويسنده , , Thomas M. Peters، نويسنده ,
Issue Information :
ماهنامه با شماره پیاپی سال 2008
Abstract :
This work developed a passive sampling method to measure ambient PM10–2.5. The coefficient of variation (CV) of PM10–2.5 measured with collocated passive samplers was 20.1% in laboratory tests and 11.6% in field tests. PM10–2.5 measured passively deviated from that measured with a filter-based dichotomous sampler by 29% in field tests. The strong correlation between PM10–2.5 derived passively with the dichotomous sampler (r=0.97) suggests that the bias observed in field tests was systematic and may be empirically corrected. The limit of detection of the method was determined to be for a 5-day sample. A bootstrap analysis suggests that at least 300 particles should be imaged to stabilize the analytical variability of the method. Repeated analysis suggests that the CV for the analytical method is 5%. This method offers an inexpensive means to assess PM10–2.5 that may be incorporated into compliance networks or epidemiological studies.
Keywords :
Coarse particulate matter , AEROSOL , PM10.2.5 , passive sampling
Journal title :
Journal of Aerosol Science
Journal title :
Journal of Aerosol Science