• Title of article

    A comparison of the former soviet union dust sampler to the u.s.a. high-volume (TSP) sampler

  • Author/Authors

    Lars Moseholm، نويسنده , , Dave Root، نويسنده , , Tim Larson، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 1996
  • Pages
    3
  • From page
    997
  • To page
    999
  • Abstract
    The particulate collection efficiency of the Former Soviet Union airborne dust sampler was assessed by operating it in parallel with the standard U.S. high-volume (TSP) sampler at University of Washington campus in Seattle, Washington. The overall collection efficiencies of the two samplers were compared. At the test site, the Former Soviet Union sampler underestimated the concentration of urban airborne particulate matter by a factor of three as measured by the colocated U.S. TSP sampler.
  • Keywords
    Former Soviet Union sampler , TSP sampler , Airborne dust , particle sampler
  • Journal title
    Atmospheric Environment
  • Serial Year
    1996
  • Journal title
    Atmospheric Environment
  • Record number

    754300