Title of article :
Validation of passive diffusion samplers for SO2 and NO2
Author/Authors :
By G. P. AYERS، نويسنده , , M. D. Keywood، نويسنده , , R. Gillett، نويسنده , , P. C. MANINS، نويسنده , , H. Malfroy، نويسنده , , T. Bardsley، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 1998
Abstract :
Passive diffusion samplers of the type described by Ferm (1991) were tested at sites in Australia for measurement of ambient levels of SO2 and NO2. For samplers exposed over periods of one to four weeks the passive diffusion samplers were found to provide quantitative measurements of these gases. Precision of the samplers, expressed as mean percentage difference between duplicates, was in the range 5–10% for NO2 at 15 ppbv and 25–10% for SO2 in the range 0.5–5 ppbv. Experiments with passive NO2 samplers of different lengths confirmed the prediction by Heal and Cape (Atmospheric Environment31, 1911–1923) of a significant artefact due to chemical reactions within the sampler, but also confirmed that the short tube length employed by the Ferm-type sampler renders this artefact insignificant for these samplers.
Keywords :
Passive sampler , monitoring , N02. , S02
Journal title :
Atmospheric Environment
Journal title :
Atmospheric Environment