Title of article :
Comparison of different methods for measuring dry deposition fluxes of particulate matter and polycyclic aromatic hydrocarbons (PAHs) in the ambient air
Author/Authors :
A.S. Shannigrahi، نويسنده , , T. Fukushima، نويسنده , , N. Ozaki، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2005
Pages :
10
From page :
653
To page :
662
Abstract :
In this study, three methods (bucket, plate for downward flux and upward flux, and water vessel) were used to measure atmospheric dry deposition fluxes at three different heights (0.5, 1.5 and 12.5 m) to estimate the deposition fluxes of mass and polycyclic aromatic hydrocarbons (PAHs) in TERC (Tsukuba), Japan. Ambient particles were also collected using a high-volume air sampler, and ambient particle size distributions between 0.01 and 13.1 μm were measured using a low-pressure cascade impactor to characterize the PAH levels and dry deposition. Settling velocities were calculated as the settling fluxes divided by the corresponding average ambient particle concentrations. In this research work, ‘we describe how small particles dominate atmospheric dry deposition of PAHs and how bucket deposition fluxes and net (downward minus upward) fluxes decrease with height due to resuspension and/or vertical distribution of suspended particles’ etc.
Keywords :
Net flux , settling velocity , Atmospheric deposition , Polycyclic aromatic hydrocarbons
Journal title :
Atmospheric Environment
Serial Year :
2005
Journal title :
Atmospheric Environment
Record number :
758602
Link To Document :
بازگشت