Title of article :
Freshwater DOC measurements by high-temperature combustion: Comparison of differential (DTC - DIC) and DIC purging methods
Author/Authors :
T. Fukushima، نويسنده , , A. Imai، نويسنده , , K. Matsushige، نويسنده , , M. Aizaki، نويسنده , , A. Otsuki، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 1996
Pages :
6
From page :
2717
To page :
2722
Abstract :
Two methods were compared for the measurement of dissolved organic carbon (DOC) in waters collected from lakes, rivers and several pollution sources. Both the differential method (D-DOC method), derived from dissolved total carbon (DTC) minus DIC (dissolved inorganic carbon), and the purging method (P-DOC method), which purges DIC, were evaluated with a Shimadzu TOC-5000 with a high temperature catalytic oxidation system. Particularly in cases of gray water and/or water which had seeped through soil-layers, considerably lower concentrations were noted for P-DOC purged at around pH 2 than those measured by the D-DOC method or the P-DOC method at pH 4. DOC measurements for both field samples and specific compounds decreased due either to precipitation or flotation of colloidal organic particles insolubilized during sparging at pH 2 or 3 or to their incomplete combustion. The D-DOC method, exhibiting lower precision than the P-DOC method particularly for samples with high DIC vs DOC ratios, is, however, recommendable because of its accuracy.
Keywords :
Dissolved organic carbon , high-temperature combustion method , DIC purging , differentialmethod , Freshwater , bias and precision
Journal title :
Water Research
Serial Year :
1996
Journal title :
Water Research
Record number :
765878
Link To Document :
بازگشت