• Title of article

    Changes at an activated sludge sewage treatment plant alter the numbers of airborne aerobic microorganisms

  • Author/Authors

    Nadeesha L. Fernando، نويسنده , , Phillip M. Fedorak، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2005
  • Pages
    12
  • From page
    4597
  • To page
    4608
  • Abstract
    In 1976, the activated sludge sewage treatment plant in Edmonton, Canada, was surveyed to determine the numbers of culturable airborne microorganisms. Many changes have been made at the plant to reduce odors and improve treatment efficiency, so in 2004 another survey was done to determine if these changes had reduced the bioaerosols. Covering the grit tanks and primary settling tanks greatly reduced the numbers of airborne microbes. Changing the design and operation of indoor automated sampling taps and sinks also reduced bioaerosols. The secondary was expanded and converted from a conventional activated sludge process using coarse bubble aeration to a biological nutrient removal system using fine bubble aeration. Although the surface area of the secondary more than doubled, the average number of airborne microorganisms in this part of the plant in 2004 was about 1% of that in 1976.
  • Keywords
    Bioaerosol , Aeration , Outdoors , Indoors , sewage
  • Journal title
    Water Research
  • Serial Year
    2005
  • Journal title
    Water Research
  • Record number