Title of article :
Surfactant effects on α-factors in aeration systems
Author/Authors :
Diego Rosso، نويسنده , , Michael K. Stenstrom، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2006
Pages :
8
From page :
1397
To page :
1404
Abstract :
Aeration in wastewater treatment processes accounts for the largest fraction of plant energy costs. Aeration systems function by shearing the surface (surface aerators) or releasing bubbles at the bottom of the tank (coarse- or fine-bubble aerators). Surfactant accumulation on gas–liquid interfaces reduces mass transfer rates, and this reduction in general is larger for fine-bubble aerators. This study evaluates mass transfer effects on the characterization and specification of aeration systems in clean and process water conditions. Tests at different interfacial turbulence regimes show higher gas transfer depression for lower turbulence regimes. Contamination effects can be offset at the expense of operating efficiency, which is characteristic of surface aerators and coarse-bubble diffusers. Results describe the variability of α-factors measured at small scale, due to uncontrolled energy density. Results are also reported in dimensionless empirical correlations describing mass transfer as a function of physiochemical and geometrical characteristics of the aeration process.
Keywords :
Aerationa-factorEfficiencyGas–liquid interfaceOxygen transferSurfactant
Journal title :
Water Research
Serial Year :
2006
Journal title :
Water Research
Record number :
772904
Link To Document :
بازگشت