• Title of article

    Surfactant effects on α-factors in aeration systems

  • Author/Authors

    Diego Rosso، نويسنده , , Michael K. Stenstrom، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2006
  • Pages
    8
  • From page
    1397
  • To page
    1404
  • Abstract
    Aeration in wastewater treatment processes accounts for the largest fraction of plant energy costs. Aeration systems function by shearing the surface (surface aerators) or releasing bubbles at the bottom of the tank (coarse- or fine-bubble aerators). Surfactant accumulation on gas–liquid interfaces reduces mass transfer rates, and this reduction in general is larger for fine-bubble aerators. This study evaluates mass transfer effects on the characterization and specification of aeration systems in clean and process water conditions. Tests at different interfacial turbulence regimes show higher gas transfer depression for lower turbulence regimes. Contamination effects can be offset at the expense of operating efficiency, which is characteristic of surface aerators and coarse-bubble diffusers. Results describe the variability of α-factors measured at small scale, due to uncontrolled energy density. Results are also reported in dimensionless empirical correlations describing mass transfer as a function of physiochemical and geometrical characteristics of the aeration process.
  • Keywords
    Aerationa-factorEfficiencyGas–liquid interfaceOxygen transferSurfactant
  • Journal title
    Water Research
  • Serial Year
    2006
  • Journal title
    Water Research
  • Record number