Title of article :
Experimental research on emission and removal of dioxins in flue gas from a co-combustion of MSW and coal incinerator
Author/Authors :
Zhaoping Zhong، نويسنده , , Baosheng Jin، نويسنده , , Yaji Huang، نويسنده , , Hongcang Zhou، نويسنده , , Jixiang Lan، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2006
Abstract :
This paper describes the experimental study of dioxins removal from flue gas from a co-combustion municipal solid waste and coal incinerator by means of a fluidized absorption tower and a fabric filter. A test rig has been set up. The flow rate of flue gas of the test rig is 150–2000 m3/h. The system was composed of a humidification and cooling system, an absorption tower, a demister, a slurry make-up tank, a desilter, a fabric filter and a measurement system. The total height of the absorption tower was 6.5 m, and the diameter of the reactor pool was 1.2 m. When the absorbent was 1% limestone slurry, the recirculation ratio was 3, the jet rate was 5–15 m/s and the submerged depth of the bubbling pipe under the slurry was 0.14 m, the removal efficiency for dioxins was 99.35%. The concentration of dioxins in the treated flue gas was 0.1573 × 10−13 kg/Nm3 and the concentration of oxygen was 11%. This concentration is comparable to the emission standards of other developed countries.
Journal title :
Waste Management
Journal title :
Waste Management