Title of article :
Referent d-dimer enzyme-linked immunosorbent assay testing is of limited value in the exclusion of thromboembolic disease: result of a practical study in an ED
Author/Authors :
Patrick Ray، نويسنده , , Bensalem Bellick، نويسنده , , Sophie Birolleau، نويسنده , , Jean-Sebastien Marx، نويسنده , , Michel Arock، نويسنده , , Bruno Riou، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2006
Abstract :
Objective
The aim of this study was to assess in clinical practice the accuracy of a referent d-dimer enzyme-linked immunosorbent assay for the exclusion of venous thromboembolic disease (VTED).
Patients and Methods
An observational prospective study took place in an emergency department; 205 consecutive outpatients suspected of having VTED were included. Blood samples were collected at admission for VIDAS DD measurement. Venous thromboembolic disease was confirmed by standard clinical imaging. All patients were followed up at 3 months.
Results
Venous thromboembolic disease was confirmed in 57 patients (28%). The sensitivity and negative predictive value of a DD assay lower than 500 ng/mL were 78% (95% confidence interval = 67%-87%) and 84% (95% confidence interval = 73%-90%), respectively. Twelve patients had a false-negative DD with one or more of the following: (a) symptoms reported for more than 15 days (n = 2), (b) prior anticoagulation (n = 3), (c) distal VTED (n = 5), or (d) high clinical probability (n = 3).
Conclusion
In our cohort of patients, DD was less accurate than previously reported, with an upper estimate of the sensitivity of only 87%.
Journal title :
American Journal of Emergency Medicine
Journal title :
American Journal of Emergency Medicine