Title of article :
Assessment of the 3-D reconstruction and high-resolution geometrical modeling of the human skeletal trunk from 2D radiographic images
Author/Authors :
J.، Dansereau, نويسنده , , S.، Delorme, نويسنده , , Y.، Petit, نويسنده , , H.، Labelle, نويسنده , , C.-E.، Aubin, نويسنده , , J.A.، De Guise, نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2003
Pages :
-988
From page :
989
To page :
0
Abstract :
This paper presents an in vivo validation of a method for the three-dimensional (3-D) high-resolution modeling of the human spine, rib cage, and pelvis for the study of spinal deformities. The method uses an adaptation of a standard close-range photogrammetry method called direct linear transformation to reconstruct the 3-D coordinates of anatomical landmarks from three radiographic images of the subjectʹs trunk. It then deforms in 3-D 1-mm-resolution anatomical primitives (reference bones) obtained by serial computed tomography-scan reconstruction of a dry specimen. The free-form deformation is calculated using dual kriging equations. In vivo validation of this method on 40 scoliotic vertebrae gives an overall accuracy of 3.3 +- 3.8 mm, making it an adequate tool for clinical studies and mechanical analysis purposes.
Keywords :
Power-aware
Journal title :
IEEE Transactions on Biomedical Engineering
Serial Year :
2003
Journal title :
IEEE Transactions on Biomedical Engineering
Record number :
80362
Link To Document :
بازگشت