• Title of article

    A prospective randomized comparison of loop recorders versus Holter monitors in patients with syncope or presyncope

  • Author/Authors

    Soori Sivakumaran، نويسنده , , Andrew D. Krahn، نويسنده , , George J. Klein، نويسنده , , Jane Finan، نويسنده , , Raymond Yee، نويسنده , , Suzanne Renner، نويسنده , , Allan C. Skanes، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2003
  • Pages
    5
  • From page
    1
  • To page
    5
  • Abstract
    Abstract Background The initial management of syncope or presyncope typically involves short-term cardiac monitoring using a Holter monitor. A loop recorder is used to extend the period of monitoring to increase the probability of obtaining a symptom-rhythm correlation. Loop recorders and Holter monitors are both used commonly, but their utility has not been compared prospectively. Methods Patients with syncope or presyncope referred for a Holter monitor or a loop recorder were assigned randomly to receive either a 48-hour Holter monitor or a loop recorder for 1 month as an initial diagnostic strategy. If the initial strategy was unsuccessful, patients were offered crossover to the alternate strategy. Results One hundred patients (mean [± SD] age, 56 ± 20 years; 44 women) with syncope (n = 21), presyncope (n = 29), or both (n = 50) were enrolled. Of the 49 patients assigned randomly to an external loop recorder first, 31 (63%) had an arrhythmia identified or excluded, versus 12 (24%) of 51 patients assigned to a Holter monitor initially (P<0.0001). Arrhythmia was identified as a cause of syncope in 1 patient with a loop recorder, compared with no patients with a Holter monitor (P = 0.31). Of the 29 patients with negative results with Holter monitoring who went on to receive a loop recorder, 13 (45%) had arrhythmia excluded, compared with none of the 4 patients who crossed over to receive a Holter monitor. The overall probability of obtaining a symptom-rhythm correlation was 56% (44/78) for loop recorders versus 22% (12/55) for Holter monitors (P<0.0001). Despite patient education and test transmissions, 13 (23%) of 57 patients who had recurrence of their symptoms failed to activate their loop recorder properly. Conclusion Loop recorders have a much higher diagnostic yield for patients with syncope or presyncope as compared with Holter monitors. The utility of loop recorders is limited by some patients’ inability to operate them correctly.
  • Journal title
    The American Journal of Medicine
  • Serial Year
    2003
  • Journal title
    The American Journal of Medicine
  • Record number

    809350