Title of article
Accuracy of bedside tissue Doppler echocardiography for the prediction of in-hospital mortality in elderly patients with acute heart failure with preserved left ventricular systolic function. Comparison with B-type natriuretic peptide measurement
Author/Authors
Stephane Arques، نويسنده , , Emmanuel Roux، نويسنده , , Pierre Ambrosi، نويسنده , , Pascal Sbragia، نويسنده , , Richard Gélisse، نويسنده , , Bertrand Pieri، نويسنده , , Roger Luccioni، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2007
Pages
4
From page
69
To page
72
Abstract
According to recent studies, tissue Doppler echocardiography used as a non-invasive surrogate for left ventricular diastolic pressures regardless of rhythm is likely to offer additional information beyond the clinical judgment and the B-type natriuretic peptide (BNP) assay in the emergency diagnosis of acute heart failure with preserved left ventricular systolic function (HFPSF). The present study attempted to determine the usefulness of bedside tissue Doppler echocardiography as compared with BNP, both obtained at presentation before unloading therapy, for the prediction of in-hospital outcome in 75 consecutive elderly patients with acute HFPSF, of whom 16 died during their in-hospital stay. Unlike BNP (p = 0.002), the spectral tissue Doppler-derived E/Ea ratio was not able to provide prognostic information in such patients before tailored therapy (p = 0.9).
Keywords
Acute heart failure , tissue Doppler , prognosis , BNP
Journal title
International Journal of Cardiology
Serial Year
2007
Journal title
International Journal of Cardiology
Record number
815566
Link To Document