• Issue Information
    ماهنامه با شماره پیاپی سال 2005
  • Pages
    14
  • From page
    624
  • To page
    637
  • Abstract
    Polymer materials considered for use in domestic hot water heating systems must maintain mechanical properties in the working fluid over their target lifetimes. In potable water, chlorine and pH combine to create an oxidative environment, commonly characterized by the oxidative reduction potential (ORP), that can chemically attack a polymer, resulting in permanent loss of mechanical strength and stiffness. Water absorption and hydrolysis can also impact polymer properties. In the present study, experiments were conducted to evaluate the mechanical performance of polysulfone, polybutylene, and polyamide 6/6 immersed for up to 1100 h in water at ORP levels of 550 and 825 mV at 60 and 80 C. Mechanical performance was evaluated by measuring creep compliance and the change in tensile strength and molecular weight after exposure. Surface morphology of the exposed materials was examined using scanning electron microscopy. Polyamide 6/6 showed significant degradation in strength and creep compliance in all environments. Despite some variability in measured properties, the blend of polybutylene, which has additives to prolong life, did not degrade. Polysulfone performed the best of the three materials with no discernable change in properties over the duration of the experiments. 2005 Published by Elsevier Ltd.
  • Journal title
    Solar Energy
  • Serial Year
    2005
  • Journal title
    Solar Energy
  • Record number

    842017