Abstract :
The purpose of this study was to develop a safe ultrasound-guided technique for biopsy
of the liver and kidneys in camels (Camelus dromedarius). Eighteen camels divided into 3
groups were used; 6 each for biopsy of the liver and right and left kidneys. Of each group, 2
were biopsied and immediately slaughtered. The remaining 4 in each group were biopsied
and then kept for 9-day observation period. When the liver was biopsied, single pass was
adequate for obtaining an adequate hepatic sample in all camels. When the right kidney
was biopsied, sufficient sample was obtained from the first endeavor in 5 of the 6 camels.
Two attempts were necessary in the other camel. When the left kidney was biopsied, sufficient
sample was obtained from the first attempt in 4 of the 6 camels. Two attempts were
necessary in one camel and 3 attempts were necessary in the remaining camel. No evidence
of immediate or delayed haematuria was observed post-biopsy. In camels with liver biopsy,
only aspartate aminotransferase was elevated (P < 0.05) for 2 days post-biopsy. When the
kidneys were biopsied, a neutrophilic leukocytosis (P < 0.05) was detected for the 24–48 h
post-biopsy. In the 6 camels immediately slaughtered after hepatic and renal biopsy, there
was a small subcutaneous haematoma. One camel with biopsy of the left kidney had a
0.8 cm subcapsular haematoma. In the 12 camels kept for 9-day observation period, there
were insignificant subcutaneous traces of blood with no gross changes indicative of peritonitis
in any of the camels. Only one camel with biopsy of the left kidney had a small
perirenal haematoma. Ultrasound-guided hepatic and renal biopsy in camels is safe, fast,
cost-effective, and practical as long as it is performed properly.