Title of article :
Input/output power scaling of a compact (0.8 L) kinetically enhanced copper-vapor laser
Author/Authors :
R.P.، Mildren, نويسنده , , G.D.، Marshall, نويسنده , , M.J.، Withford, نويسنده , , D.W.، Coutts, نويسنده , , J.A.، Piper, نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2003
Abstract :
We report the performance of a kinetically enhanced copper-vapor laser of active dimensions 32-mm inner diameter by 1-m long as a function of the plasma tube thermal insulation. By reducing the insulation to levels much lower than typically used for conventional copper-vapor lasers, the input power for maximum steady-state output increased from 5.9 to 7.4 kW, whereas the laser wall-plug efficiency was constant at approximately 1.4%. At the highest input power, we obtained 104 W at the specific output power 130 W/liter. The depletion of Cu atoms from the axial region by gas heating and ion-pumping depletion is similar to that of copper-vapor lasers having much lower specific input power and the laser gain remains peaked on-axis.
Keywords :
filtering , ranked output , Performance
Journal title :
IEEE JOURNAL OF QUANTUM ELECTRONICS
Journal title :