Title of article :
New developments in French transient monitoring system: SYSFAC from the experiments to the industrial process Original Research Article
Author/Authors :
J. Balley، نويسنده , , D. Bertagnolio، نويسنده , , C. Faidy، نويسنده , , F. Kappler، نويسنده , , M. Kergoat، نويسنده , , Y. LʹHuby، نويسنده , , P. Genette، نويسنده , , D. Savoldelli، نويسنده , , I. Fournier، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 1995
Pages :
7
From page :
145
To page :
151
Abstract :
After more than 15 years of experience with regulatory transient data collection, Electricité de France decided to design a new concept of fatigue monitoring system called SYSFAC. This new system is the result of seven years of successful experimentation with fatigue meters. This system will be connected to the on-site data acquisition system without any complementary instrumentation. The SYSFAC system has a modular structure: the mechanical transient module, the functional transient module, the fatigue meters module and the global damage computing module all have a high level of flexibility to be applied to various types of circuits. After the preliminary studies had been achieved, it was decided to undertake the industrial phase of the SYSFAC project. Specific codes on PC computers have been used to validate the basic concepts and the operator interface. Real-size coding will last one year and the first SYSFAC system will be delivered to the pilot power plant by the end of 1995.
Journal title :
Nuclear Engineering and Design Eslah
Serial Year :
1995
Journal title :
Nuclear Engineering and Design Eslah
Record number :
887773
Link To Document :
بازگشت