Title of article
The passive ALWR approach to assuring containment integrity Original Research Article
Author/Authors
John C. Devine Jr.، نويسنده , , William Layman، نويسنده , , David E.W. Leaver، نويسنده , , Joseph Santucci، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 1995
Pages
12
From page
469
To page
480
Abstract
Design requirements for the advanced light water reactor (ALWR) have been developed so as to provide high assurance of containment integrity even in the event of a severe accident. The containment integrity requirements are in the form of two design criteria, and associated methodology, which address containment severe accident performance and offsite dose and are specified in the ALWR utility requirements document (URD), a set of detailed design requirements for next generation plants in the US.
The containment performance criterion, which is the main focus of this paper, specifies that plant design characteristics and features shall be provided to preclude core damage sequences which could bypass containment and to withstand core damage sequence loads. This containment performance capability, along with the associated dose mitigation capability, provides a technical basis for emergency planning change since there would not be the same need for rapid offsite emergency response that is called for under the existing US emergency planning basis.
Journal title
Nuclear Engineering and Design Eslah
Serial Year
1995
Journal title
Nuclear Engineering and Design Eslah
Record number
887900
Link To Document