Evaluation of subcooled critical heat flux correlations for tubes with and without internal twisted tapes Original Research Article
Author/Authors :
F. Inasaka، نويسنده , , H. Nariai، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 1996
Abstract :
Eleven correlations and models for critical heat flux (CHF) of subcooled flow boiling in water were evaluated. Both a direct substitution method (DSM) and a heat balance condition method (HBM) were compared in the evaluations. The HBM was recommended as a better prediction method in the present study. For straight tubes under uniform heating conditions, the correlations of the Gunther, Knoebel, modified Tong, W-2, and Tong-75, and also the Celata and Weisman-Pei models were confirmed to give reasonably good predictions. Among them, the Celata model was the best with respect to accuracy. For swirl flow under uniform heating conditions. Tong-75-I (involving modification of the water velocity parameter) and Nariai-Inasaka correlations were confirmed to give reasonably good predictions, even though their predictions were too low for the CHF under non-uniform heating conditions.