Title of article
Post test calculations to 11% break loca experiments on the integral test facility ISB-VVER using the thermalhydraulic code ATHLET
Author/Authors
Eckhard Krepper، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 1997
Pages
5
From page
3
To page
7
Abstract
The considered test was a break on the upper plenum with different modes of emergency core cooling. The reference case was the non-availability of emergency cooling. Injecting the emergency coolant into the cold leg, no increasing of rod cladding temperatures was observed, but natural circulation instabilities occurred. Injecting the cooling into the hot leg, the cooling situation was getting worse. Due to the injected cold emergency coolant, the fluid density in the discharge volume was enhanced and the break mass flow increased. The observed events in the test were reproduced by the code with good agreement.
Journal title
Nuclear Engineering and Design Eslah
Serial Year
1997
Journal title
Nuclear Engineering and Design Eslah
Record number
888216
Link To Document