Title of article
An independent assessment of Groeneveld et al.ʹs 1995 CHF look-up table Original Research Article
Author/Authors
Won Pil Baek، نويسنده , , Hong-Chae Kim، نويسنده , , Soon Heung Chang، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 1997
Pages
7
From page
331
To page
337
Abstract
The prediction capability of the 1995 CHF look-up table (Groeneveld D.C., et al., Nucl. Eng. Des. 163 (1996) 1–23) is independently assessed based on the KAIST data base consisting of 10 822 data for uniformly-heated, vertical, round tubes. This confirms the error statistics for the heat balance method reported by Groeneveld et al. and shows overall average and RMS errors of 4.2 and 36.7%, respectively, for the direct substitution method. The new 1995 table shows better prediction capability than the 1986 AECL-UO table (), especially for the low-pressure, low-flow region. The error analysis indicates the length effect even for significantly long tubes.
Journal title
Nuclear Engineering and Design Eslah
Serial Year
1997
Journal title
Nuclear Engineering and Design Eslah
Record number
888462
Link To Document