Title of article
Examination of transient characteristics of two-phase natural circulation within a Freon-113 boiling/condensation loop Original Research Article
Author/Authors
Koichi Tanimoto، نويسنده , , Mamoru Ishii، نويسنده , , Sang Yong Lee، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 1998
Pages
19
From page
77
To page
95
Abstract
Transient characteristics of two-phase natural circulation within a Freon-113 loop with a large condenser have been examined mainly focused on the flashing phenomenon. General behavior was described and parametric studies were performed. The items observed were the period and duration of flashing, peak flow rate, amount of flow carryover per flashing, lowest-peak liquid level within the condenser, and the peak void distribution in the riser section. The parameters considered were the heater power input, valve friction at the heater inlet (simulating the loopwise friction), condenser cooling, degree of subcooling at the heater inlet, and the heat loss to the surroundings. As a whole, the heater power input, valve friction, and the rate of condenser cooling played important roles in flashing while the other effects being marginal. In general, the flow appeared to be more unstable with the larger condensing surface which causes the condensation-induced flashing.
Journal title
Nuclear Engineering and Design Eslah
Serial Year
1998
Journal title
Nuclear Engineering and Design Eslah
Record number
888562
Link To Document