Title of article :
Operating experience with an on-line vibration control system for PWR main coolant pumps Original Research Article
Author/Authors :
J Runkel، نويسنده , , D Stegemann، نويسنده , , A Vortriede، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 1998
Pages :
11
From page :
157
To page :
167
Abstract :
The main circulation pumps are key components of nuclear power plants with pressurized water reactors (PWRs), because the availability of the main circulation pumps has a direct influence on the availability and electrical output of the entire plant. The on-line automatic vibration control system ASMAS was developed for early failure detection during the normal operation of the main circulation pumps in order to avoid unexpected outages and to establish the possibility of preventive maintenance of the pumps. This system is permanently and successfully operating in three German 1300 MWel NPPʹs with PWR and has been successfully tested in a 350 MWel NPP with a PWR.