• Title of article

    Analyses of subcooled CCFL tests for evaluation of W̱COBRA/TRAC applicability Original Research Article

  • Author/Authors

    K Takeuchi، نويسنده , , M.E Nissley، نويسنده , , M.Y Young، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 1998
  • Pages
    14
  • From page
    127
  • To page
    140
  • Abstract
    The W̱COBRA/TRAC-MOD7A, Rev. 1 code is currently licensed for best estimate large break LOCA analyses of 3 and 4 loop PWRs with emergency core cooling system injection located in the cold legs. As a part of the licensing effort to extend the code applicability to an upper plenum injection plant, the codes ability to predict subcooled flooding on a perforated plate was assessed by analyses of GE counter current flow limit tests and by comparison to the Bankoff flooding correlation (Bankoff, S.G., Tankin, R.S., Yuen, M.C., Hsieh, C., 1981). Counter current flow of air/water and steam/water through a horizontal perforated plate, Int. J. Heat Mass Transfer, 24 (8) 1382). The observed code model bias for subcooled CCFL can be eliminated by applying multiplication factors to the interfacial condensation and the interfacial drag models.
  • Journal title
    Nuclear Engineering and Design Eslah
  • Serial Year
    1998
  • Journal title
    Nuclear Engineering and Design Eslah
  • Record number

    888618