Experimental evaluation of the limiting critical quality values in circular and non-circular flow geometries Original Research Article
Author/Authors
I.L Pioro، نويسنده , , S.C. Cheng، نويسنده , , A.? Vasi?، نويسنده , , I Salah، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 1999
Pages
23
From page
317
To page
339
Abstract
An experimental evaluation of the limiting critical quality (or limiting quality in short) values in different flow geometries (circular, rectangular, triangular, and dumb-bell shaped) was performed using R-134a as a coolant. The limiting quality characterized by a sharp drop of critical heat flux (CHF) is affected by the following geometric parameters: hydraulic-equivalent diameter, channel shape, and gap size. The effect of flow geometry on limiting quality is influenced by flow parameters (pressure and mass flux). The effects of these parameters on limiting quality and CHF were examined, and recommendations for predicting the limiting quality in circular and non-circular geometries have been made.