Abstract
An analysis of the physical processes taking place in a dispersed-annular flow which govern dry-out type CHFs has been carried out. The analysis has shown that the number of variables required to describe the critical phenomena can be reduced by the introduction of a new parameter: the length over which dispersed-annular flow takes place, Ldan. In this case only, for a given tube diameter, pressure and mass flux, the critical heat flux may be expressed in terms of a single variable: Ldan. A correlation which may be used to determine this length has also been developed. The representation of the CHF data obtained at low pressures in terms of the coordinate system (Ldan, q″cr) has shown that the dispersion of the data about the regression curves is considerably reduced as compared with the traditional presentation of the critical heat flux as a function of the thermodynamic quality at the end of the heated length.