Title of article :
Modeling of eddy current probe response for steam generator tubes Original Research Article
Author/Authors :
S Bakhtiari، نويسنده , , D.S Kupperman، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 1999
Pages :
15
From page :
57
To page :
71
Abstract :
Sample calculations were performed with a three-dimensional (3D) finite-element model to describe the response of an eddy current (EC) probe to defects in steam generator (SG) tubing. Such calculations could be very helpful in understanding and interpreting EC probe response to complex tube/defect geometries associated with the inservice inspection (ISI) of SG tubes. The governing field equations are in terms of coupled magnetic vector and electric scalar potentials in conducting media and of total or reduced scalar potentials in nonconducting regions. To establish the validity of the model, comparisons of the theoretical and experimental responses of an absolute bobbin probe are given for two types of calibration standard defects. Simulation results are also presented on the effect of ligament size in axial cracks on bobbin probe response.
Journal title :
Nuclear Engineering and Design Eslah
Serial Year :
1999
Journal title :
Nuclear Engineering and Design Eslah
Record number :
889012
Link To Document :
بازگشت