• Title of article

    Measurement of heat transfer coefficients for direct contact condensation in core makeup tanks using holographic interferometer Original Research Article

  • Author/Authors

    Seong Hun Ju، نويسنده , , Hee Cheon No، نويسنده , , Franz Mayinger، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2000
  • Pages
    9
  • From page
    75
  • To page
    83
  • Abstract
    The present work is to improve our understanding and analysis of direct contact condensation on the gravity injection of CMTs and to measure the heat transfer coefficients around steam bubbles using the holographic interferometer and high speed camera. The condensation regime map associated with the downward injection of steam into water through the steam pipe is investigated to understand the mechanism of the direct contact condensation. The present map shows that the boundary of chugging and subsonic jetting with the larger diameter pipe is shifted to the larger steam mass flux. Steam cavity mode, not found in the literature, and the unique mode of downward injection for the present geometry, is observed at the low subcooled water temperature. With the holographic interferometry and the high speed camera, the heat transfer mechanism for the direct contact condensation in CMTs is understood and the heat transfer coefficients are measured.
  • Journal title
    Nuclear Engineering and Design Eslah
  • Serial Year
    2000
  • Journal title
    Nuclear Engineering and Design Eslah
  • Record number

    889144