• Title of article

    An experimental study on evaporative heat transfer coefficient and applications for passive cooling of AP600 steel containment Original Research Article

  • Author/Authors

    Y.M. Kang، نويسنده , , G.C. Park، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2001
  • Pages
    13
  • From page
    347
  • To page
    359
  • Abstract
    After TMI and Chernobyl accidents, many efforts have been made to enhance the nuclear safety with passive features. Among such passive features, the passive containment cooling system (PCCS) has been suggested by Westinghouse in the AP600 plant. The containment with PCCS is a dual containment, and consists of a stainless steel vessel and a concrete wall. In the gap between these structures, air and water can counter-currently pass and cool the steel surface. This paper experimentally investigates evaporative heat and mass transfer at the surface of a falling water film with counter-current air flow in a vertical duct with one-side heated plate. Experiments included various conditions of mass flow rate of film and air. Experimental results show the strong effects of water temperature and air mass flow rate, but little effect of the water flow rate. Also, simple analyses based on heat and mass transfer analogy were performed to evaluate the experimental results. With experimental data, a new correlation on evaporative mass transfer coefficient was developed, and with the correlation, the containment pressure and temperature was calculated for the design basis accident of AP600 by the use of CONTEMPT4/MOD5 code implementation.
  • Journal title
    Nuclear Engineering and Design Eslah
  • Serial Year
    2001
  • Journal title
    Nuclear Engineering and Design Eslah
  • Record number

    889287