• Title of article

    Investigation on the interaction effect of two parallel axial through-wall cracks existing in steam generator tube Original Research Article

  • Author/Authors

    Youn-Won Park، نويسنده , , Myung Ho Song، نويسنده , , Jin-Ho Lee، نويسنده , , Seong Hwan Moon، نويسنده , , Young Jin Kim، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2002
  • Pages
    11
  • From page
    13
  • To page
    23
  • Abstract
    It is commonly required that steam generator tubes wall-thinned in excess of 40% should be plugged. However, the plugging criterion is known to be too conservative for some locations and types of defects and its application is confined to a single crack. In the previous study, the conservatism of the present plugging criterion of steam generator tubes was reviewed and a crack coalescence model applicable to steam generator tubes with two collinear axial through-wall cracks was proposed. Since parallel axial cracks are more frequently detected during in-service inspections than collinear axial cracks, the studies on parallel axial cracks spaced in circumferential direction are necessary. The objective of this paper is to investigate the interaction effect between two parallel axial through-wall cracks existing in a steam generator tube. Finite element analyses were performed and a new failure model of the steam generator tube with these types of cracks is suggested. Interaction effects between two adjacent cracks were investigated to explain the deformation behavior of cracked tubes.
  • Journal title
    Nuclear Engineering and Design Eslah
  • Serial Year
    2002
  • Journal title
    Nuclear Engineering and Design Eslah
  • Record number

    889523