Title of article :
RALOC4 code validation against measured data at Ignalina NPP during single Main Safety Valve opening Original Research Article
Author/Authors :
E. Urbonavicius، نويسنده , , S. Rimkevicius، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2002
Abstract :
Although RALOC4 code is validated against many experiments with regard to Western Nuclear Power Plants (NPPs) the code validation problem for the Accident Localization System (ALS) of Ignalina NPP modeling is of special importance because the condensing pools at NPP with RBMK-1500 differ from the pressure suppression systems installed in NPPs with German BWR. The response of Ignalina NPP ALS to the unintentional opening of single Main Safety Valve, which occurred in 1998, is analyzed by employing code RALOC4. The results of post-event calculations compared with the measured data available after the event. The performed analysis showed that RALOC4 code could be applied for the simulation of Ignalina NPP ALS. Nevertheless, the spray modeling in RALOC4 should be improved allowing the simulation of sprays in NON_EQUILIBRIUM zone model and to consider the diameter of water droplet diameter and height of droplet fall.
Journal title :
Nuclear Engineering and Design Eslah
Journal title :
Nuclear Engineering and Design Eslah