Title of article
The helium purification system of the HTR-10 Original Research Article
Author/Authors
M.S. Yao، نويسنده , , R.P. Wang، نويسنده , , Z.Y. Liu، نويسنده , , X.D. He، نويسنده , , J. Li، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2002
Pages
5
From page
163
To page
167
Abstract
In order to reduce the quantity of chemical impurities in the primary coolant helium and to remove the gaseous radionuclide fission products, a helium purification system mainly composed of a copper oxide bed, a molecular sieve adsorber and a low temperature adsorber is designed for the HTR-10. One actual purification train is designed for a helium flow rate of 10.5 kg h−1, corresponding with a 5% gas change of the helium inventory in primary circuit. It is anticipated that more than 2000 h continuous purification operation will be reached between regeneration.
Journal title
Nuclear Engineering and Design Eslah
Serial Year
2002
Journal title
Nuclear Engineering and Design Eslah
Record number
889619
Link To Document