Title of article :
Buckling assessment procedure for large diameter vessel with local thin area subjected to combined pressure and external moment Original Research Article
Author/Authors :
N. Mukaimachi، نويسنده , , S. Konosu، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2009
Pages :
10
From page :
221
To page :
230
Abstract :
The newly developed p-M diagram provides a means for readily evaluating the collapse and/or buckling load of pressure equipment with external flaws simultaneously subjected to internal pressure, p and external bending moment, M due to earthquake, etc. In this paper, some FEAs for large diameter vessels with an external flaw were conducted under (1) pure external bending moment, and (2) subjected simultaneously to both internal pressure and external bending moment, in order to determine the plastic collapse load by applying the twice-elastic slope (TES) as recommended by the ASME and to determine the buckling load. The p-M line adopted in the Ibaraki FFS rule based on the measured yield stress indicates that the safety margin for the TES loads at the LTA is about 1.2–1.8, and 1.5–2.0 for the buckling loads. The Ibaraki FFS rule that prevents buckling by applying Donnellʹs equation of FS = 2 can assure adequate levels of integrity and safety.
Journal title :
Nuclear Engineering and Design Eslah
Serial Year :
2009
Journal title :
Nuclear Engineering and Design Eslah
Record number :
895232
Link To Document :
بازگشت