Title of article :
Thermal-fluid flow analysis and demonstration test of a spent fuel storage system Original Research Article
Author/Authors :
J.C. Lee، نويسنده , , W.S Choi، نويسنده , , K.S. Bang، نويسنده , , K.S. Seo، نويسنده , , S.Y. Yoo، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2009
Pages :
8
From page :
551
To page :
558
Abstract :
Thermal-fluid flow analysis and demonstration test were performed for a spent fuel storage system. The commercial computational fluid dynamics (CFD) code, FLUENT was used for the numerical analysis. Effective thermal conductivities of a spent fuel assembly and a fuel basket were derived to optimize a thermal analysis model. Also, a porous model, which can simplify a complex configuration of a fuel assembly, was used in the thermal analysis. Demonstration test were performed to verify the thermal analysis method and procedure using a half scaled-down model and an electrically heated dummy fuel. The numerical analysis results were compared with the experimental data. Thermal analyses of the storage system were carried out for normal and off-normal conditions by using the verified analysis method.
Journal title :
Nuclear Engineering and Design Eslah
Serial Year :
2009
Journal title :
Nuclear Engineering and Design Eslah
Record number :
895269
Link To Document :
بازگشت