Title of article :
Actual flow calibration of a feedwater flowmeter using a high Reynolds number facility at NMIJ Original Research Article
Author/Authors :
Noriyuki Furuichi، نويسنده , , Yoshiya Terao، نويسنده , , Masaki Takamoto، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2009
Abstract :
The results of calibration tests of the feedwater flowrate of ultrasonic flowmeters used in a nuclear power plant for variety of upstream conditions obtained using the new high Reynolds number calibration facility at NMIJ are described. In this examination, the measurements are performed for five pattern pipe layouts with one or two elbows. The flow conditioners installed upstream of the flowmeter are the tube bundle type and the Mitsubishi, which are normally used in nuclear power plants. The calibration result for each flowmeter are largely different for each flow conditioner and each upstream pipe layout, except in some special cases. Moreover, the trend of the correction factor with Reynolds number is not uniform for each case. Furthermore, some differences were observed for individual flowmeters. It is recommended that the feedwater flowmeter, especially when used to perform measurement uncertainty recapture, is calibrated based on the actual pipe layout and the Reynolds number corresponding to the actual nuclear power plant conditions.
Journal title :
Nuclear Engineering and Design Eslah
Journal title :