Title of article :
Comparison between wire-mesh sensors and conductive needle-probes for measurements of two-phase flow parameters Original Research Article
Author/Authors :
A. Manera، نويسنده , , B. Ozar، نويسنده , , S. Paranjape، نويسنده , , M. Ishii، نويسنده , , H.-M. Prasser، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2009
Pages :
7
From page :
1718
To page :
1724
Abstract :
Measurements of two-phase flow parameters such as void-fraction, bubble velocities, and interfacial area density have been performed in an upwards air–water flow at atmospheric pressure by means of a four-tip needle-probe and a wire-mesh sensor. For the first time, a direct comparison between the two measuring techniques has been carried out. Both techniques are based on the measurement of the fluid conductivity. For void-fraction and velocity measurements, similarity exists between the two methodologies for signal analysis. A significantly different approach is followed, instead, for the estimation of the interfacial area concentration: while the evaluation based on the needle-probe signal is carried out by using projections of the gas–liquid interface velocity, the evaluation based on the wire-mesh signals consist in a full reconstruction of the bubbles interfaces. The comparison between the two techniques shows a good agreement.
Journal title :
Nuclear Engineering and Design Eslah
Serial Year :
2009
Journal title :
Nuclear Engineering and Design Eslah
Record number :
895378
Link To Document :
بازگشت