Title of article :
Experimental and theoretical comparison of fuel temperature and bulk coolant characteristics in the Oregon State TRIGA® reactor during steady state operation Original Research Article
Author/Authors :
W.R. Marcum، نويسنده , , B.G. Woods، نويسنده , , S.R. Reese، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2010
Abstract :
In September of 2008 Oregon State University (OSU) completed its core conversion analysis as part of the Reduced Enrichment for Research and Test Reactors (RERTR) Program. Experimental bulk coolant temperatures were collected in various locations throughout the Oregon State TRIGA® Reactor (OSTR) core in order to supplement the validity of the numerical thermal hydraulic results produced in RELAP5-3D Version 2.4.2.
Axial bulk coolant temperature distributions were collected by acquiring discrete thermocouple measurements in individual subchannel locations during steady state operation at 1.0 MWth. The experimental axial temperature distribution collected was compared to one-channel, two-channel, and eight-channel RELAP5-3D models and found to match within 11.94%, 11.69%, and 8.78%, respectively, on average. Comparisons to similar studies were made based on a dimensional analysis of fluid body forces in the discrete core locations, indicating that the chosen approach produces conservative results for use in the OSTR safety analysis.
Journal title :
Nuclear Engineering and Design Eslah
Journal title :
Nuclear Engineering and Design Eslah