Title of article :
Thermal hydraulic behavior in the deteriorated turbulent heat transfer regime for a gas-cooled reactor Original Research Article
Author/Authors :
Hyeonil Kim، نويسنده , , Jeong Ik Lee، نويسنده , , Hee Cheon No، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2010
Pages :
13
From page :
783
To page :
795
Abstract :
One of the key issues in a gas-cooled system with a passive heat removal measure is the correct prediction of thermal hydraulic behavior in the deteriorated turbulent heat transfer (DTHT) regime. Here, a simple one-dimensional analysis of a gas-cooled reactor system was performed to show its strong potential for operation in the DTHT regime. A numerical calculation using computational fluid dynamics (CFD) was done to verify the capability of the Launder–Sharma (LS) turbulence model to predict wall and bulk temperatures while a gas system is operating in the DTHT regime. The results by the LS model are compared to those by the high Reynolds turbulent model, a newly proposed correlation, and recently obtained experimental data. The comparison shows that the LS turbulence model can provide a reasonable prediction in the buoyancy-induced DTHT regime. Additionally, it was found that the LS model predicted strong laminarization near the entrance which deteriorated turbulent heat transfer further compared to the measurements, but re-turbulization took place much earlier than in the experiment which recovered the heat transfer to a normal turbulent heat transfer.
Journal title :
Nuclear Engineering and Design Eslah
Serial Year :
2010
Journal title :
Nuclear Engineering and Design Eslah
Record number :
895611
Link To Document :
بازگشت