Author/Authors :
Shahab Khushnood، نويسنده , , Zaffar Muhammad Khan، نويسنده , , Muhammad Afzaal Malik، نويسنده , , Qamar Iqbal، نويسنده , , Sajid Bashir، نويسنده , , Muddasar Khan، نويسنده , , Zafarullah Koreshi، نويسنده , , Mahmood Anwar Khan، نويسنده , , Tahir Nadeem Malik، نويسنده , , Arshad Hussain Qureshi، نويسنده ,
Abstract :
Most structures and equipment used in nuclear power plant and process plant, such as reactor internals, fuel rods, steam generator tubes bundles, and process heat exchanger tube bundles, are subjected to flow-induced vibrations (FIV). Costly plant shutdowns have been the source of motivation for continuing studies on cross-flow-induced vibration in these structures. Damping has been the target of various research attempts related to FIV in tube bundles. A recent research attempt has shown the usefulness of a phenomenon termed as ‘thermal damping’. The current paper focuses on the modeling and analysis of thermal damping in tube bundles subjected to cross-flow. It is expected that the present attempt will help in establishing improved design guidelines with respect to damping in tube bundles.
Keywords :
Modeling and analysis , Thermal damping , Cross-flow-induced vibration , Tube bundles