Title of article :
The best column number for enrichment of heavy water in thermal-diffusion columns of countercurrent-flow Frazier scheme with total sum of column height fixed Original Research Article
Author/Authors :
Ho-Ming Yeh، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2010
Pages :
5
From page :
2800
To page :
2804
Abstract :
The effect of column number N and the same column height h of each thermal-diffusion column, on the Frazier scheme performance with total sum of column height (L = Nh) fixed, has been investigated. The equations, which may be employed to predict the optimal number of columns (generally not integers) for the maximum performance are derived. Accordingly, the best number of columns, which are the integers nearest to, and small than the optimal column numbers, are obtained for practical applications. Considerable improvement in performance is obtainable if the scheme is constructed with the best number of thermal-diffusion columns, instead of using a single column with column height L (N = 1, h = L). This is because that increasing column height in a thermal-diffusion column, though increasing the performance, will decrease the increment in performance, and finally the performance reaches a limiting value.
Journal title :
Nuclear Engineering and Design Eslah
Serial Year :
2010
Journal title :
Nuclear Engineering and Design Eslah
Record number :
895818
Link To Document :
بازگشت