Title of article :
Progress in measurements of a single-electron pump by means of a CCC
Author/Authors :
F.، Piquemal, نويسنده , , S.V.، Lotkhov, نويسنده , , A.B.، Zorin, نويسنده , , N.، Feltin, نويسنده , , L.، Devoille, نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2003
Pages :
-598
From page :
599
To page :
0
Abstract :
This paper deals with the improvements of the BNM-LNE experimental setup based on a cryogenic current comparator (CCC) devoted to the high-accuracy measurement of current delivered by a single-electron tunneling pump. A three-junction Cr-Al R-pump, fabricated by the PTB, has been fully characterized. First current steps have been observed at pumping frequencies up to 30 MHz. At 10 MHz, for which I=1.6 pA, the current step is found to be flat within +-15 fA (5 min of measurement) over a bias voltage range of 200 (mu)V. At the middle of the step, currents of a few pA have been measured with a type-A uncertainty as low as 12 aA which results from a 12-h measurement. Although the CCC has not been used in its optimal operating mode, the results demonstrate the possibility to measure the current generated by a single-electron tunneling pump with type-A uncertainties as low as a few parts in 10^6.
Keywords :
leukemia
Journal title :
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT
Serial Year :
2003
Journal title :
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT
Record number :
91538
Link To Document :
بازگشت